ANDEROL 755 Synthetic Compressor Lubricant Product Data Sheet PROPERTIES TEST METHOD ANDEROL 755 Appearance @ 20°C Viscosity @ 40°C, cSt Viscosity @ 100°C, cSt Viscosity Index Density @ 15°C, kg/l Total Acid Number, mg KOH/g Flash Point, °C Pour Point, °C Demulsibility @ 82°C,min Sulphated ash Air release, min % CRC of 20% dest Carbon conradson residue, % Evaporation loss, % visual ASTM D-445 ASTM D-445 ASTM D-2270 ASTM D-1298 ASTM D-664 ASTM D-92 ASTM D-97 ASTM D-1401 DIN 51575 ASTM D-3427 DIN 51536 ASTM D-189 ASTM D-972 Clear Yellow Liquid 136.3 12.6 81 0.964 0.05 264 -39 10 0.011 3.2 0.098 0.1 0.3 APROVALS / REGISTRATIONS ANDEROL 755 is an ISO 150 synthetic diester based compressor lubricant specifically designed to provide long-term lubrication in air and process gas compressors. ANDEROL 755 meets or exceeds the following specifications: DIN 51506 VDL, ISO 6743-3 L-DVC ADVANTAGES / BENEFITS COMPATIBILITY APPLICATION No metal additives to interfere with catalytic processes ● Fewer oil changes ● Reduces compressor maintenance ● Greatly reduces fire and explosion hazard ● Separates water condensate rapidly ● Lower oil consumption ● Eliminates lacquering and deposits Reduces energy consumption The following seals, paints and plastics are recommended for use in contact with Anderol synthetic lubricants. Materials not recommended are also shown. For more information on other materials see our ‘Compatibility Guide’. RECOMMENDED: Viton, High Nitrile Buna N, Teflon, Epoxy Paint, Oil-Resistant Alkyd, Nylon, Delrin, Celcon, PBT NOT RECOMMENDED: Neoprene, SBR Rubber, Low Nitrile Buna N, Acrylic Paint, Lacquer, Polystyrene, PVC, ABS FOR MORE INFORMATION PLEASE REFER TO THE RELEVANT MATERIAL SAFETY DATA SHEET This information is furnished without warranty, representation, inducement, or license of any kind except that it is accurate to the best of OUR knowledge or obtained from sources believed by ANDEROL to be accurate. ANDEROL does not assume any legal responsibility for use of reliance upon it. Only Chemists or chemically qualified lab technicians should carry out tests. Before using any chemicals, read its label and Material Safety Data Sheet. ANDEROL BV Punterweg 2 |